Mega & Ultrasonic Watt Meter WM-2008

* Digital Meter: Displays Peak, Avg., Reflected Watts
* Calibrated and Certified Generator output
* Monitor Generator performance
* Automatically control over/under power
* Save Data for analysis
* Monitor up to 4 generators from Watt meter
* Remote control via software
* BNC Connectors for Oscilloscope Output
* 40 kHz to 15 mHz Frequency Range
* Up to 2000 Watts Power with end connectors
* Sensors Available for lower Frequencies
* NIST Calibrated
* Can be used with and without computer
* Version available with L-2001 ultrasonic probe for in tank        measurements [Model WM-2009-P]

 

Watt Meter Screens

The Ultra /Mega Sonic Watt Meter allows the calibration and certification of your Ultra / Mega Sonic generator to NIST standards. More companies are requiring calibration and certification of all production equipment. The Watt Meter will provide this certification as well as preventing the loss of product though improper cleaning.

Sensor Module with Scope V/A connectors


Sensor Module

Digital Measurement Console Attaches to Computer

Up to 4 individual Ultrasonic or Mega Sonic tanks can be monitored at one time, A software controlled relay will shut down any tank that exceeds its set point.

The Ultra / Mega Sonic Watt meter and controller consists of a digital meter, up to 4 individual sensors and computer software that allows the complete monitoring of the generator output.  The generator outputs are connected to a sensor module and then to the generator. The sensor displays the Peak, Average and Reflected power on the LCD meter face. A built in relay can control or send and output signal  to an alarm or to a relay to shut off the Mega Sonic unit or to sound an alarm. The sensor relays the information to the Watt Meter and to an output [BNC] connector for an Oscilloscope. Up to 4 individual generators can be monitored using one Watt Meter.

The Information is also displayed on the watt meters own software via a USB connection installed in a laptop or other computer.

The generator can be easily calibrated by using the watt meter and its own software alone or in combination with an Oscilloscope. 

An output port on the Watt Meter sends a signal to a relay that can be used to either sound an alarm or turn off any generator that exhibits a high or low power output. The Watt Meter software has a number of screens that display the peak and average power output of the generator.  The data can be saved and used with other programs, such as spread sheet or math cad software. Additionally the watt meter displays the reflected power present in the cable. Increasing reflected power indicates a problem with the transducers or the generator.

Each sensor has 2 additional BNC connectors for a PC based oscilloscope that will display the wave forms for Volts, Amps and Frequency on its software. This is invaluable for analyzing and tuning the phase of the generator. Several types of PC scopes are available for use with the WM-2008

The TM associates Watt meter offers a NIST calibrated instrument that allows up to 4 different Mega Sonic tanks to be calibrated and monitored at an exceedingly reasonable cost. 

When used with our L-2001-4MS probe system the combination of the 2 instruments allows complete monitoring and evaluation both of the generator power and the expressed power in the Mega Sonic bath. The L-2001-4MS displays Power, Spectrum Analysis and process power within the Mega Sonic bath. See our Data Sheet on the L-2001-4 for more information

Watt Meter WM-2008 Connection Lay Out for generator monitoring

Watt MeterWM-2008-P with Ultrasonic Probe configuration

The WM-2008-P Watt meter has one of the 4 sensor ports dedicated and specially adapted to allow the connection of our L-2001 ultrasonic probe. The probe will read the direct watts in the actual cleaning fluid of the ultrasonic or megasonic tank and display that result on a Bargraph and on the Digital Meter. The probe can also be used with the Oscilloscope as a stand alone instrument for displaying wave form, frequency, and spectral analysis of the actual tank power .

With the combination of the watt meter and the probe you can compare the power output of the generator with the actual power in the tank. This combination gives you a compete tool for the analysis of any ultrasonic or mega sonic process.

PC Based Oscilloscopes

USB5200 Oscilloscope

Bandwidth 40MHz, 60MHz, 100MHz or 200MHz, Sampling rate 100, 150, 250 or 500MS/s in real time, Equivalent Sampling 50GS/s, Measurement via USB interface, Measurement data can be stored and processed immediately when connected. The oscilloscope screen is similar to the ones of customary oscilloscopes. Operating the Oscilloscope Attachment is mere child's play owin

Description:
Bandwidth 40MHz, 60MHz, 100MHz or 200MHz,

Sampling rate 100, 150, 250 or 500MS/s in real time, Equivalent Sampling 50GS/s, Measurement via USB interface,

Measurement data can be stored and processed immediately when connected. The oscilloscope screen is similar to the ones of customary oscilloscopes. Operating the Oscilloscope Attachment is mere child's play owing to the unit's auto-set function which enables automatic adaptation of settings to the respective measuring signal, and to its comprehensive range of trigger functions.

The true USB2.0 interface allows fast data transfer rate that ensures a quick screen update rate, even when collecting large amounts of data.

The plug&play character is very convenient for user to set up and connect the instrument to PC.The device is powered directly from the USB bus that eliminates the transformer.

 

 The  DSO2300 is an intelligent 8-bit two-channel PC-based USB digital storage oscilloscope. It runs on any PC equipped with USB1.1 or USB2.0 using Windows 98/2000/XP. The USB cable provided also supplies power to the unit, so no external power supply is needed. It has up to 100 Ms/s real-time sampling rate and 50MHz bandwidth. The device combines the functions of a frequency spectrum analyzer, waveform recorder, signal generator, cymometer, voltmeter, acoustic analysis graphic instrument, mathematical related graphic instrument voltage meter, and digital storage oscilloscope. All these functions are controlled through a point-and-click PC software interface. It is a small, handheld device that is ideal for engineers, students and anyone looking for an easy-to-use, low-cost and powerful oscilloscope.

DSO2300 Digital Oscilloscope Features
   * Size: 144 x 88 x 38 mm (excluding cable and probes)
    * Weight: less than 0.25 kg (excluding accessories)
    * Metal case
    * Plug and Play operation
    * Powered through USB
    * Multi-functional: Frequency spectrum analyzer, waveform recorder, signal generator, cymometer, voltmeter, acoustic analysis graphic instrument, mathematical related graphic instrument voltage meter, digital storage oscilloscope, etc.
    * Record and play. The computer can not only save the current waveform on the screen, but also record a continuous waveform. The operation of record and playback are just like using a DVD player.
    * Data can be imported into Excel, Word or plain text formats. You can therefore generate report forms that take full advantage of Excel's powerful diagram functions.
    * Zoom features with active cursors and waveform can be saved as a .jpg file
    * Capable of providing intuitive professional diagrams like FFT waveform / Lissajous pattern (X-Y PLOT) waveform / S MAP / C MAP
    * Variables of the input signal can be calculated and displayed. User can adjust the displayed location and color. All variables can be copied to Excel, Word, etc.
    * Online auto calibration
    * Trigger settings allow both horizontal and vertical trigger position settings
    * Either of the two channels can be the trigger of the other
    * Waveform can be printed online
    * User interface can be changed. Knobs can be selected with 3D style or plain style.
    * Easy to use with various color settings and a point-and-click PC software interface
    * Intelligent waveform searching and tracing function
    * Simple Copy and Paste into other applications such as Word and Excel
    * Channel-interactive mathematical operations
    * User can save and restore the settings
    * One PC can work with several DSO2300 oscilloscopes so that more channels can be observed
    * Inherits the advantage of a traditional instrument with friendly human-machine interface and ease of use

 

    *  The Handyscope HS3 is a powerful computer controlled measuring instrument that consists of four measuring instruments: a Multimeter, an Oscilloscope, a Spectrum analyzer and a Transient recorder. An AWG is also available. This new powerful and compact measuring instrument can solve almost every measurement problem.

    * The Handyscope HS3 features a user selectable 12 bit, 14 bit or 16 bit resolution (14 bit effective, SNR 95 dB), 200 mV - 80 V full scale input range, 128 Ksamples record length per channel and a sampling frequency up to 100 MHz on both channels (100 MHz only in 8 bit resolution).

    * The integrated AWG operates fully independent from the measuring system of the Handyscope HS3. It has a 50 MHz sampling clock, a 256K samples deep waveform memory, a 14 bit output resolution and a ± 12 Volt output range. The AWG allows you to generate test signals for your measurements in any shape you like. Several standard signal shapes are available and it is possible to regenerate previous measured signals.

    * Connected to the fast USB 2.0 (High Speed, 480 Mbit/s), the Handyscope HS3 doesn't require an external power supply, therefore the Handyscope HS3 easily complies to "Plug in and measure".

    * The universal software that is delivered with the Handyscope HS3 turns your PC into a storage oscilloscope, a spectrum analyzer, a voltmeter and a transient recorder. An intelligent auto setup allows the inexperienced user to perform measurements immediately. The software allows you to save instrument settings on disk. Later these setting files can be recalled, reducing the setup time of your instrument to an absolute minimum.

    * Besides measuring in block mode, the Handyscope HS3 is also capable of performing continuous streaming measurements. This will create a continuous uninterrupted data stream to the computer. The data can then be displayed on the screen and/or saved to disk.

Display channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH1, CH2, CH1 and CH2

Display mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Envelope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On/Off

Averaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.. 256 averaging

Math mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH1+CH2, CH1-CH2, CH2-CH1

Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal, Invert

Vertical position setting . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mVolt, 500mVolt, 1V, 2V, 5V, 10V, 20V, 40V 80 Volt full scale

Vertical gain setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 to 8 magnifying

Input coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC/DC

Time base minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 day's/div

Time base maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100nsec/div (model HS3-100MHz)

200nsec/div (model HS3-50MHz)

400nsec/div (model HS3-25MHz)

1ìsec/div (model HS3-10MHz)

2ìsec/div (model HS3-5MHz)

Time base gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 125 magnifying

Record length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 131060 samples per channel

Record view scroll bar gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 125

Trigger mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . free run, auto, single, edge triggered, window, peak, external

Trigger system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . two digital trigger levels, 4096 positions

Trigger source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH1, CH2, External, Keyboard and Generator

Trigger level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-100% full input range

Pre trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 131060 samples per channel

Post trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 131060 samples per channel

Trigger hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 100% full input range

Trigger hysteresis resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.025 % full scale

Auto disk measuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 1000 file's

Auto setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . connect and show

Zooming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mouse window control, gain vertical and gain horizontal

Cursor system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . two cursors, autotracking, auto correct points

Cursor mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . large cursors, small cursors

Cursor measurements: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . rise time left

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . rise time right

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . sample time left

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . sample time right

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . sample time difference

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cursor frequency

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage left

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage right

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage difference

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . slew rate left

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . slew rate right

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Phase difference in Degrees, Radials or cos()

Color settings . . . . . . . . . . . . . . . . . . . . CH1, CH2, Ref CH1, Ref CH2, math, trigger, timebase, background, raster, cursors

Fonts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . user selectable

Voltmeter

Display channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH1, CH2, CH1 and CH2

Display size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . user selectable

Number of displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 6 user selectable

Frequency range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hz to 10 MHz, model HS3-50 and HS3-100

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hz to 2 MHz, model HS3-10 and HS3-25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hz to 500 kHz, model HS3-5

Full scale reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 counts

Accuracy DC coupled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2% ±10 counts

Accuracy AC coupled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 % ±10 counts(10 to 1 MHz)

0.7 % ±20 counts(1 MHz